homepage contact

Defro Akm Uni

The construction is based on DEFRO AKM boilers equipped with the innovative APPS UNI trough burner. The boiler retained all advantages of the basic model. Exposed to fire elements of heat exchanger have been made from boiler steel of thickness of 8 mm. The combustion chamber has been equipped with ceramic catalysts stabilising the combustion process and making it more effective and efficient. The DEFRO AKM UNI boilers cooperate with the APPS UNI fuel charger, which allows for using many types of solid fuels such as fines, pea coal, pellet or grains. Additionally, the boilers have been equipped with a cast iron supplementary grate allowing for using other fuels and start-up of the device in emergency cases.
The boilers have been equipped with elements increasing usage safety including dual protection against fuel ignition in the charge container and an automatic water system – FIRE-FIGHTER. Upon request, the charge container can additionally be equipped with a lamp increasing the comfort of usage.

 
defro-akm-uni-przekroj
Fuel type:
primary
ekogroszek mial_weglowy pellet
pea-coal fine coal pellet

substitute
owies wegiel-groszek drewno_wiory
wheat pea coal, nut coal wood, edgings, shavings (on the substitute furnace)

Boiler’s advantages:
gwarancja-5
5-year warranty for heat exchanger tightness, 2-year warranty for other elements and efficient operation of the boiler;
stal-6-8 the exchanger has been made from certified boiler steel ( P256GH type) of thickness of 6-8 mm, delivered by the following steel plants: Arcelor Mittal Poland S.A, Kraków branch and U. S. Steel Košice s.r.o.;
sprawnosc-88
high thermal efficiency over 88%;
duza-komora-rynna
bottom combustion chamber with a highly-effective trough burner;
czujnik-klapy fuel-container opening sensor;
sterownik-4 programmer cooperating with 4 pumps (central heating and hot utility water, circulatory, on the floor, with output for a room controller), and with the possibility of controlling mixing valves*
gaszenie-paliwa automatic water system for quenching fuel, includes a thermostatic valve*;
ruszt-zeliwny replaceable secondary grate made from high-quality heat resistant cast iron;
Technical data
Unit 15 22 30 40 50
Nominal output kW 6-17 9-29 10-32 14-46 17-56
Heating surface m2 1,5 2,6 2,9 4,1 5,2
Heated room surface m2 up to 150 up to 220 up to 280 up to 360 up to 480
Single fuel load kg 105 152 152 256 256
Optimum heating efficiency % 85,1-88,6 85,1-88,6 85,1-88,6 85,1-88,6 85,1-88,6
Max. work pressure allowed bar 1,5 1,5 1,5 1,5 1,5
Required chimney flue Pa 24 27 30 32 34
Water temp. on supply max °C 80 80 80 80 80
Boiler weight kg 385 497 542 675 750
Boiler water capacity l ~63 ~105 ~115 ~148 ~174
Chimney cross section cm x cm
ø mm
14x14
160
16x16
180
18x18
200
19x19
220
21x21
210
Minimum chimney height m 5 5 6 8 9
Power supply
V/Hz 230/50 230/50 230/50 230/50 230/50
Power consumption
W 163 163 289 289 289
Width mm 428 428 478 578 628
Depth mm 1617 1820 1820 1820 1820
Height* mm 1408 1508 1508 1590 1590
Supply and return diameter Dn mm G 11/2" G 11/2" G 11/2" G 11/2" G 11/2"
Flue pipe dimension mm ø159 ø159 ø178 ø194 ø194
Height to the lower end of flue pipe* mm 1284 1444 1444 1544 1644
*Boiler’s height can be additionally regulated by the use of the feet attached to it. The feet can regulate height by 38-50mm.

defro-akm-uni-wymiary

 
A* B* C D* E* F
G
H
I
J
15 106 1284 Ø159 1408 1218 428 536 618 200 1617
22 106 1444 Ø159 1508 1378 428 566 818 200 1820
30 106 1444 Ø179 1508 1378 478 586 818 200 1820
40 106 1544 Ø194 1590 1478 578 642 818 200 1820
50 106 1644 Ø194 1590 1578 628 650 818 200 1820
* In case of disclaimers of regulatory dimension increases from min. 38 to max. 50 mm.

The table below shows the dimensions of the opening for filling and combustion chamber.

 
A
(Width)
B
(Depth)
C
(Height)
D
(Width x Height)
defro-akm-uni-wymiary-przekroj
15 254 215 300 254x188
22 254 405 300 254x238
30 304 340 320 304x238
40 404 315 360 404x238
50 454 315 360 454x238





 
DEFRO Company reserves the right to change without notice the technical parameters, equipment and specifications of our products. Contained on this page to ensure the information is not in the meaning. 4. 3 and 4 of the Act of 27 July 2002 on the specific terms of consumer sales and amending the Civil Code (the "Act") and do not describe the purpose of a product. 4. 2 of the Act. This site does not constitute an offer within the meaning of. 1966 Civil Code.


stal-6-8