Defro Duo Pellet Lux
|
DEFRO DUO PELLET LUX is an offer for the most demanding Customers who value quality as well as design. The fuel charging system has been modified. The boilers are characterised by advanced controlling automatics, which allows for maintenance-free boiler operation for a few days. |
![]() |
||||||||||||||||||||
| Boiler’s advantages: | |||||||||||||||||||||
| basic | replacement | ||||||||||||||||||||
![]() |
![]() |
![]() |
|||||||||||||||||||
| pellet | coal | wood logs | |||||||||||||||||||
|
|||||||||||||||||||||
| Technical data | ||||||
| Specification/boiler type |
Unit
|
15
|
25
|
35
|
50
|
75 |
| Nominal output |
kW
|
8-24
|
10-31
|
13-42
|
16-53
|
23-75 |
| Heating surface |
m2
|
2,1
|
2,8
|
3,8
|
4,8
|
6,7 |
| Heated room surface |
m2
|
up to 200
|
up to 250
|
up to 320
|
up to 480
|
up to 700 |
| Single fuel load |
kg
|
~240
|
~370
|
~390
|
~530
|
~530 |
| Optimum heating efficiency |
%
|
90,1-92,5
|
90,1-92,5
|
90,1-92,5
|
90,1-92,5
|
90,1-92,5 |
| Max. work pressure allowed |
bar
|
1,5
|
1,5
|
1,5
|
1,5
|
1,5 |
| Required chimney flue |
Pa
|
20
|
25
|
30
|
35
|
38 |
| Water temp. on supply max |
°C
|
85
|
85
|
85
|
85
|
85
|
| Boiler weight |
kg
|
524
|
605
|
665
|
861
|
1010 |
| Boiler water capacity |
l
|
76
|
99
|
110
|
122
|
197 |
| Chimney cross section |
cm x cm
ø mm |
14x14
160 |
16x16
180 |
19x19
210 |
21x21
230 |
25x25 280 |
| Minimum chimney height |
m
|
6
|
6
|
7
|
9
|
10 |
| Power supply |
V/Hz
|
230/50
|
230/50
|
230/50
|
230/50
|
230/50
|
| Power consumption - boiler start-up |
W | 287(272) |
287(272) | 316(301) | 316(301) | 316(301) |
| Power consumption - boiler operation | W | 97(82) | 97(82) | 126(111) | 126(111) | 126(111) |
| Width |
mm
|
1313
|
1498
|
1548
|
1548
|
1648 |
| Depth |
mm
|
925
|
1031
|
1065
|
1283
|
1295 |
| Height* |
mm
|
1672
|
1672
|
1739
|
1739
|
1878 |
| Supply and return diameter Dn |
mm
|
G 11/2"
|
G 11/2"
|
G 11/2"
|
G 11/2"
|
G 2"
|
| Flue pipe dimension |
mm
|
ø159
|
ø178
|
ø194
|
ø194
|
ø245
|
| Height to the lower end of flue pipe* | mm | 1257 | 1257 | 1305 | 1305 | 1402 |
| * Boiler’s height can be additionally regulated by the use of the feet attached to it. The feet can regulate height by 38-50mm. | ||||||
![]() |
||||||||||||
| A* | B* | C | D* | E* | F | G | H | I | J | K | L | |
| 15 | 115 | 1257 | Ø159 | 1688 | 1526 | 498 | 1313 | 533 | 210 | 202 | 945 | 715 |
| 25 | 115 | 1257 | Ø179 | 1688 | 1526 | 548 | 1498 | 641 | 210 | 202 | 1053 | 850 |
| 35 | 115 | 1305 | Ø194 | 1733 | 1571 | 598 | 1548 | 641 | 240 | 202 | 1083 | 850 |
| 50 | 115 | 1305 | Ø194 | 1733 | 1571 | 598 | 1578 | 865 | 240 | 202 | 1307 | 850 |
| 75 | 153 | 1402 | Ø245 | 1879 | 1575 | 698 | 1648 | 865 | 240 | 202 | 1307 | 850 |
| * In case of disclaimers of regulatory dimension increases from min. 38 to max. 50 mm. | |||||
| The table below shows the dimensions of the opening for filling and combustion chamber. | |||||
| A (Width) |
B (Depth) |
C (Height) |
D (Width x Height) |
![]() |
|
| 15 | 310 | 370 | 310 | 310x190 | |
| 25 | 360 | 480 | 310 | 360x190 | |
| 35 | 405 | 480 | 360 | 405x190 | |
| 50 | 405 | 700 | 360 | 405x190 | |
| 75 | 500 | 700 | 410 | 500x235 | |
|
DEFRO Company reserves the right to change without notice the technical parameters, equipment and specifications of our products. Contained on this page to ensure the information is not in the meaning. 4. 3 and 4 of the Act of 27 July 2002 on the specific terms of consumer sales and amending the Civil Code (the "Act") and do not describe the purpose of a product. 4. 2 of the Act. This site does not constitute an offer within the meaning of. 1966 Civil Code.
|