homepage contact

Defro Duo Pellet

The DEFRO DUO PELLET boilers have been created on the basis of the DEFRO DUO series. The main difference consists in the fuel charger and burner adjusted for trees' leaf biomass in the form of pellets. The biggest advantage of the boilers constitute advanced automatics - programmer controlling central heating, hot utility water and two other pumps as wells as the mixing valve and the self-acting system: ignition, fuel charging and burner cleaning.
The additional chamber created by a stationary grate cooled by water (wall thickness: 8.8 mm) allows for temporary use of other types of fuel such as wood chips and boiler start-up in emergency cases. The boilers are equipped with a number of sensors controlling its work. Moreover, the charge container can be equipped with a lamp increasing the comfort of operation.

  
defro-duo-pellet-przekroj
Fuel type:
primary substitute
pellet wegiel-orzech drewno_kawalki
pellet coal wood
Boiler’s advantages:
gwarancja-5
5-year warranty for heat exchanger tightness, 2-year warranty for other elements and efficient operation of the boiler;
stal-6-10 the exchanger has been made from certified boiler steel ( P256GH type) of thickness of 6-10 mm, delivered by the following steel plants: Arcelor Mittal Poland S.A, Kraków branch and U. S. Steel Košice s.r.o.;
sprawnosc-92
high thermal efficiency, up to 92%, thanks to increased heat recovery from flue gas;
samoczynny-zaplon
self-acting fuel ignition system connected to the automatic burner cleaning system;
auto-manual
two combustion chambers: lower with an automatic retort burner and upper for burning wood (when charged manually);
sterownik-4
electronic boiler regulation; innovative controller with a touch screen cooperating with up to 4 pumps (central heating, hot utility water, circulatory and floor pump) and with the possibility of controlling mixing valves*;
oswietlenie
internal lamp for the charge container*;
* additional option, installed at customer request
Technical data
Unit
15
25
35
50
75
Nominal output
kW
8-24
10-31
13-42
16-53
23-75
Heating surface
m2
2,1
2,8
3,8
4,8
6,7
Heated room surface
m2
up to 200
up to 250
up to 320
up to 480
up to 700
Single fuel load
kg
~180
~180
~350
~350
~400
Optimum heating efficiency
%
90,1-92,5
90,1-92,5
90,1-92,5
90,1-92,5
90,1-92,5
Max. work pressure allowed
bar
1,5
1,5
1,5
1,5
1,5
Required chimney flue
Pa
20
25
30
35
38
Water temp. on supply max
°C
85
85
85
85
85
Boiler weight
kg
548
609
711
897
1041
Boiler water capacity
l
76
99
110
122
197
Chimney cross section
cm x cm
ø mm
14x14
160
16x16
180
19x19
210
21x21
230
25x25
280
Minimum chimney height
m
6
6
7
9
10
Power supply
V/Hz
230/50
230/50
230/50
230/50
230/50
Power consumption - boiler start-up
W 287 (272)
287 (272) 316 (301)
316 (301) 316 (301)
Power consumption - boiler operation W 97 (82)
97 (82) 126 (111) 126 (111) 126 (111)
Width
mm
1915
1965
2115
2115
2215
Depth
mm
925
1031
1065
1283
1295
Height*
mm
1672
1672
1739
1739
1878
Supply and return diameter Dn
mm
G 11/2"
G 11/2"
G 11/2"
G 11/2"
G 2"
Flue pipe dimension
mm
ø159
ø179
ø194
ø194
ø245
*Boiler’s height can be additionally regulated by the use of the feet attached to it. The feet can regulate height by 38-50mm.
defro-duo-pellet-wymiary
  A* B* C D* E* F G H I J K L
15 115 1257 Ø159 1712 1539 498 535 1800 533 210 945 732
25 115 1257 Ø179 1712 1539 548 535 1900 641 210 1053 732
35 115 1305 Ø194 1759 1591 598 775 2400 641 240 1083 865
50 115 1305 Ø194 1759 1591 598 775 2400 865 240 1307 865
75 153 1402 Ø245 1898 1591 718 775 2550 865 250 1317 865
* In case of disclaimers of regulatory dimension increases from min. 38 to max. 50 mm.
The table below shows the dimensions of the opening for filling and combustion chamber.
  A
(Width)
B
(Depth)
C
(Height)
D
(Width x Height)
defro-duo-pellet-wymiary-przekroj
15 310 370 310 310x190
25 360 480 310 360x190
35 405 480 360 405x190
50 405 700 360 405x190
75 500 700 410 500x235
 
DEFRO Company reserves the right to change without notice the technical parameters, equipment and specifications of our products. Contained on this page to ensure the information is not in the meaning. 4. 3 and 4 of the Act of 27 July 2002 on the specific terms of consumer sales and amending the Civil Code (the "Act") and do not describe the purpose of a product. 4. 2 of the Act. This site does not constitute an offer within the meaning of. 1966 Civil Code.


stal-6-10