homepage contact

Defro Eko Duo

DEFRO EKO DUO is another boiler model with two combustion chambers: lower with an automatic retort burner for pea coal, and upper - created by means of a grate cooled by water and of wall thickness of 8.8 mm. The chamber of traditional combustion allows for temporary usage of other fuels as well as starting up the device in emergency cases. A grate deck has also the function of water tubes and constitutes additional area for heat exchange. The exchanger has been made from certified boiler steel of thickness of 6-8 mm***.
In order to reduce the loss of heat, additional thermal insulation has been applied. The following optional equipment is available: charge container drying system protecting against corrosion of the water quenching system in case of flame return to the fuel charger pipe and a lamp for the charge container improving the comfort of work. On request, the boiler can be equipped with an innovative controller with a touch screen.

defro-eko-duo-przekroj
  
Boiler’s advantages:
basic
ekogroszek wegiel-groszek drewno_wiory
pea coal coal /nut/ pea coal wood, edgings, shavings
Boiler’s advantages:
gwarancja-5
5-year warranty for heat exchanger tightness, 2-year warranty for other elements and efficient operation of the boiler;
stal-6-8 the exchanger has been made from certified boiler steel ( P256GH type) of thickness of 6-8 mm, delivered by the following steel plants: Arcelor Mittal Poland S.A, Kraków branch and U. S. Steel Košice s.r.o.;
sprawnosc-89
high thermal efficiency, up to 89%, thanks to increased heat recovery from flue gas;
sterownik-4
electronic boiler regulation; innovative controller with a touch screen cooperating with up to 4 pumps (central heating, hot utility water, circulatory and floor pump) and with the possibility of controlling mixing valves*;
duza-komora-retort-obrotowy
bottom combustion chamber with a highly-effective rotary retort burner;
auto-manual two combustion chambers: lower with an automatic retort burner and upper for burning wood (when charged manually);
gaszenie-paliwa automatic water system for quenching fuel, includes a thermostatic valve*;
czujnik-klapy fuel-container opening sensor; 
Technical data
Unit
19
28
38
50
75
Nominal output
kW
8-26
11-35
13-43
17-55
24-79
Heating surface
m2
2,3
3,1
3,9
5,0
7,1
Heated room surface
m2
do 190
do 270
do 360
do 480
do 720
Single fuel load
kg
~210
~210
~210
~390
~390
Optimum heating efficiency
%
~87
~87
~87
~87
~87
Max. work pressure allowed
bar
1,5
1,5
1,5
1,5
1,5
Required chimney flue
Pa
25
29
39
45
70
Water temp. on supply max
°C
80
80
80
80
80
Boiler weight
kg
530
620
690
805
1050
Boiler water capacity
l
68
87
106
135
180
Chimney cross section
cm x cm
ø mm
14x14
160
16x16
180
18x18
200
19x19
210
24x24
270
Minimum chimney height
m
8
9
10
10
11
Zasilanie
V/Hz
230/50
230/50
230/50
230/50
230/50
Pobór mocy
W
158
158
264
264
354
Width
mm
1370
1395
1446
1446
1535
Depth
mm
1055
1145
1245
1365
1535
Height*
mm
1360
1360
1380
1480
1580
Supply and return diameter Dn
mm
G 11/2"
G 11/2"
G 11/2"
G 11/2"
G 2"
Flue pipe dimension
mm
ø178
ø178
ø194
ø194
ø245
Height to the lower end of flue pipe* mm 919 919 931 931 1080
*Boiler’s height can be additionally regulated by the use of the feet attached to it. The feet can regulate height by 38-50mm.
defro-eko-wymiary
  A* B* C D* E* F G H I J K L
19 387 919 Ø179 1360 1360 488 56 1370 747 110 178 1055
28 387 919 Ø179 1360 1360 538 56 1395 857 110 198 1145
38 387 931 Ø179 1380 1360 588 56 1446 957 110 198 1245
50 387 931 Ø179 1480 1480 588 56 1446 1077 110 198 1365
75 387 1080 Ø179 1580 1580 688 56 1535 1227 110 198 1535
* In case of disclaimers of regulatory dimension increases from min. 38 to max. 50 mm.
The table below shows the dimensions of the opening for filling and combustion chamber.
  A
(Width)
B
(Depth)
C
(Height)
D
(Width x Height)
defro-eko-duo-wymiary-przekroj
19 304 355 245 304x164
28 354 355 245 354x164
38 404 455 245 404x184
50 404 455 305 404x234
75 504 605 395 504x234
 
DEFRO Company reserves the right to change without notice the technical parameters, equipment and specifications of our products. Contained on this page to ensure the information is not in the meaning. 4. 3 and 4 of the Act of 27 July 2002 on the specific terms of consumer sales and amending the Civil Code (the "Act") and do not describe the purpose of a product. 4. 2 of the Act. This site does not constitute an offer within the meaning of. 1966 Civil Code.


stal-6-8