Defro Eko Duo Uni
|
The DEFRO EKO UNI boilers have been created on the basis of the DEFRO EKO DUO UNI series. The DUO series is characterised by two combustion chambers: the lower chamber has been equipped with an innovative trough burner allowing for using pea coal, qualified fines as well as biomass in the form of pellet and grains. The upper chamber constitutes a cast iron grate cooled by water, which allows for temporary usage of other fuels as well as starting up the device in emergency cases. The exchanger has been made from certified boiler steel of thickness of 6-8 mm***, it has also thermal insulation reducing the loss of heat. Places significantly exposed to the loss of heat are equipped with additional thermal insulation. The boilers have been equipped with elements increasing usage safety. Standard equipment is as follows: the FIREFIGHTER water quenching system (in case of flame return to the fuel charger pipe) as well as the door-opening sensor. A lamp for the charge container improves the comfort of work. On request, the boiler can be equipped with an innovative controller with a touch screen. |
![]() |
|||||||||||||||||||
| Boiler’s advantages: | ||||||||||||||||||||
| basic | ||||||||||||||||||||
![]() |
![]() |
![]() |
||||||||||||||||||
| pea coal | fine coal | pellet | ||||||||||||||||||
| replacement | ||||||||||||||||||||
![]() |
![]() |
![]() |
||||||||||||||||||
| oat | coal /nut/ | wood, edgings, shavings | ||||||||||||||||||
|
||||||||||||||||||||
|
Technical data
|
|||||
| Specification/boiler type |
Unit
|
19
|
28
|
38
|
50
|
| Nominal output |
kW
|
8-26
|
11-35
|
13-43
|
17-55
|
| Heating surface |
m2
|
2,6
|
3,6
|
4,3
|
5,4
|
| Heated room surface |
m2
|
up to 190
|
up to 270
|
up to 360
|
up to 480
|
| Single fuel load |
kg
|
~210
|
~210
|
~210
|
~390
|
| Optimum heating efficiency |
%
|
88,2-89,8
|
88,2-89,8
|
88,2-89,8
|
88,2-89,8
|
| Max. work pressure allowed |
bar
|
1,5
|
1,5
|
1,5
|
1,5
|
| Required chimney flue |
Pa
|
25
|
29
|
32
|
34
|
| Water temp. on supply min/max |
°C
|
55/85
|
55/85
|
55/85
|
55/85
|
| Boiler weight |
kg
|
589
|
679
|
775
|
820
|
| Boiler water capacity |
l
|
78
|
101
|
119
|
145
|
| Chimney cross section |
cm x cm
ø mm |
14x14
160 |
16x16
180 |
18x18
200 |
19x19
210 |
| Minimum chimney height |
m
|
8
|
9
|
10
|
10
|
| Power supply |
V/Hz
|
230/50
|
230/50
|
230/50
|
230/50
|
| Power consumption |
W
|
158
|
158
|
264
|
264
|
| Width |
mm
|
1292
|
1322
|
1382
|
1382
|
| Depth |
mm
|
1034
|
1144
|
1244
|
|
| Height* |
mm
|
1360
|
1360
|
1380
|
1480
|
| Supply and return diameter Dn |
mm
|
G 11/2"
|
G 11/2"
|
G 11/2"
|
G 11/2"
|
| Flue pipe dimension |
mm
|
ø178
|
ø178
|
ø194
|
ø194
|
| Height to the lower end of flue pipe* | mm | 919 | 919 | 931 | 931 |
| *Boiler’s height can be additionally regulated by the use of the feet attached to it. The feet can regulate height by 38-50mm. | |||||
![]() |
||||||||||||
| A* | B* | C | D* | E* | F | G | H | I | J | K | L | |
| 19 | 387 | 919 | Ø179 | 1360 | 1360 | 488 | 56 | 1325 | 747 | 110 | 178 | 1055 |
| 28 | 387 | 919 | Ø179 | 1360 | 1360 | 538 | 56 | 1375 | 857 | 110 | 198 | 1145 |
| 38 | 387 | 931 | Ø194 | 1380 | 1360 | 588 | 56 | 1421 | 957 | 110 | 198 | 1245 |
| 50 | 387 | 931 | Ø194 | 1480 | 1480 | 588 | 56 | 1421 | 1077 | 110 | 198 | 1365 |
| 75 | 393 | 1080 | Ø245 | 1580 | 1580 | 688 | 56 | - | 1227 | 110 | 198 | 1535 |
| * In case of disclaimers of regulatory dimension increases from min. 38 to max. 50 mm. | |||||
| The table below shows the dimensions of the opening for filling and combustion chamber. | |||||
| A (Width) |
B (Depth) |
C (Height) |
D (Width x Height) |
![]() |
|
| 19 | 304 | 355 | 245 | 304x164 | |
| 28 | 354 | 355 | 245 | 354x164 | |
| 38 | 404 | 455 | 245 | 404x184 | |
| 50 | 404 | 455 | 305 | 404x234 | |
| 75 | 504 | 605 | 395 | 504x234 | |
|
DEFRO Company reserves the right to change without notice the technical parameters, equipment and specifications of our products. Contained on this page to ensure the information is not in the meaning. 4. 3 and 4 of the Act of 27 July 2002 on the specific terms of consumer sales and amending the Civil Code (the "Act") and do not describe the purpose of a product. 4. 2 of the Act. This site does not constitute an offer within the meaning of. 1966 Civil Code.
|