Defro Eko
|
Optimised location of heat exchanger plates and reduced number of welded joints are only some of new solutions in the new DEFRO EKO series. The heat exchanger has been made from boiler steel of thickness of 6-8 mm***. The increased wall thickness and using boiler steel increases durability of the boiler. The combustion chamber has been equipped with a retort furnace with automatic fuel charge from a container located next to the boiler. The combustion process is controlled by means of a programmer and what needs to be done is filling the container with fuel, periodical removal of ash and cleaning the boiler. The DEFRO EKO boilers are equipped with an additional cast iron grate, which allows for emergency operation of the device even in case of a power cut. A fuel-container opening sensor is a standard equipment of the boiler. In order to facilitate boiler installation and usage, the DEFRO EKO boilers have been equipped with adjustable legs for boiler levelling, flue extension with draught regulator as well as the solution allowing for dual-side door installation. On request, the boiler can be equipped with an innovative controller with a touch screen. |
![]() |
|||||||||||||||||||
| Boiler’s advantages: | ||||||||||||||||||||
| basic | replacement | |||||||||||||||||||
![]() |
![]() |
![]() |
||||||||||||||||||
| peal coal | coal | wood, edgings, shavings | ||||||||||||||||||
|
||||||||||||||||||||
|
Technical data
|
||||||
| Specification/boiler type |
Unit
|
19
|
28
|
38
|
50
|
75
|
| Nominal output |
kW
|
8-26
|
11-35
|
13-43
|
17-55
|
24-79
|
| Heating surface |
m2
|
2,4
|
3,3
|
4,0
|
5,0
|
7,0
|
| Heated room surface |
m2
|
up to 190
|
up to 270
|
up to 360
|
up to 480
|
up to 720
|
| Single fuel load |
kg
|
~210
|
~210
|
~210
|
~390
|
~390
|
| Optimum heating efficiency |
%
|
88,2-89,8
|
88,2-89,8
|
88,2-89,8
|
88,2-89,8
|
88,2-89,8
|
| Max. work pressure allowed |
bar
|
1,5
|
1,5
|
1,5
|
1,5
|
1,5
|
| Required chimney flue |
Pa
|
25
|
29
|
32
|
34
|
38
|
| Water temp. on supply max |
°C
|
80
|
80
|
80
|
80
|
80
|
| Boiler weight |
kg
|
574
|
703
|
789
|
842
|
1145
|
| Boiler water capacity |
l
|
77
|
99
|
116
|
142
|
191
|
| Chimney cross section |
cm x cm
ø mm |
14x14
160 |
16x16
180 |
18x18
200 |
19x19
210 |
24x24
270 |
| Minimum chimney height |
m
|
8
|
9
|
10
|
10
|
11
|
| Power supply |
V/Hz
|
230/50
|
230/50
|
230/50
|
230/50
|
230/50
|
| Power consumption |
W
|
165
|
214 |
291
|
291
|
346
|
| Width |
mm
|
1310
|
1335
|
1446
|
1386
|
1583
|
| Depth |
mm
|
1034
|
1144
|
1244
|
1364
|
1535
|
| Height* |
mm
|
1360
|
1360
|
1380
|
1480
|
1580
|
| Supply and return diameter Dn |
mm
|
G 11/2"
|
G 11/2"
|
G 11/2"
|
G 11/2"
|
G 2"
|
| Flue pipe dimension |
mm
|
ø178
|
ø178
|
ø194
|
ø194
|
ø245
|
| Height to the lower end of flue pipe* | mm | 919 | 919 | 931 | 931 | 1080 |
| *Boiler’s height can be additionally regulated by the use of the feet attached to it. The feet can regulate height by 38-50mm. | ||||||
![]() |
||||||||||||
| A* | B* | C | D* | E* | F | G | H | I | J | K | L | |
| 19 | 387 | 919 | Ø179 | 1360 | 1360 | 488 | 56 | 1370 | 747 | 110 | 178 | 1055 |
| 28 | 387 | 919 | Ø179 | 1360 | 1360 | 538 | 56 | 1395 | 857 | 110 | 198 | 1145 |
| 38 | 387 | 931 | Ø179 | 1380 | 1360 | 588 | 56 | 1446 | 957 | 110 | 198 | 1245 |
| 50 | 387 | 931 | Ø179 | 1480 | 1480 | 588 | 56 | 1446 | 1077 | 110 | 198 | 1365 |
| 75 | 387 | 1080 | Ø179 | 1580 | 1580 | 688 | 56 | 1535 | 1227 | 110 | 198 | 1535 |
| * In case of disclaimers of regulatory dimension increases from min. 38 to max. 50 mm. | |||||
| The table below shows the dimensions of the opening for filling and combustion chamber. | |||||
| A (Width) |
B (Depth) |
C (Height) |
D (Width x Height) |
![]() |
|
| 19 | 304 | 355 | 245 | 304x164 | |
| 28 | 354 | 355 | 245 | 354x164 | |
| 38 | 404 | 455 | 245 | 404x184 | |
| 50 | 404 | 455 | 305 | 404x234 | |
| 75 | 504 | 605 | 395 | 504x234 | |
|
DEFRO Company reserves the right to change without notice the technical parameters, equipment and specifications of our products. Contained on this page to ensure the information is not in the meaning. 4. 3 and 4 of the Act of 27 July 2002 on the specific terms of consumer sales and amending the Civil Code (the "Act") and do not describe the purpose of a product. 4. 2 of the Act. This site does not constitute an offer within the meaning of. 1966 Civil Code.
|