Defro Eko Uni
|
Another boiler from the DEFRO EKO series - the UNI version has been equipped with the APPS UNI fuel charger. The burner used allows for using different types of solid fuels such as pea coal, qualified fines, biomass in the form of pellet as well as grains, e.g. oat. The burner has been equipped with an innovative solution of secondary charging, which facilitates the process of combustion and makes it more ecological. The combustion chamber has been equipped with ceramic catalysts stabilising the combustion process and making it more effective and efficient. The DEFRO EKO UNI boilers are equipped with an additional cast iron grate, which allows for emergency operation of the device even in case of a power cut. The boilers have been equipped with elements increasing usage safety. Standard equipment is as follows: the FIRE-FIGHTER water quenching system (in case of flame return to the fuel charger pipe) as well as the door-opening sensor. A lamp for the charge container improves the comfort of work. On request, the boiler can be equipped with an innovative controller with a touch screen. |
![]() |
|||||||||||||||||||
| Boiler’s advantages: | ||||||||||||||||||||
| basic | ||||||||||||||||||||
![]() |
![]() |
![]() |
||||||||||||||||||
| pea-coal | fine coal | pellet | ||||||||||||||||||
| replacement | ||||||||||||||||||||
![]() |
![]() |
![]() |
||||||||||||||||||
| oat | coal /nut/ | wood, edgings, shavings | ||||||||||||||||||
|
||||||||||||||||||||
|
Technical data
|
|||||
| Specification/boiler type |
Unit
|
19
|
28
|
38
|
50
|
| Nominal output |
kW
|
8-26
|
11-35
|
13-43
|
17-55
|
| Heating surface |
m2
|
2,4
|
3,3
|
4,0
|
5,0
|
| Heated room surface |
m2
|
up to 190
|
up to 270
|
up to 360
|
up to 480
|
| Single fuel load |
kg
|
~210
|
~210
|
~210
|
~390
|
| Optimum heating efficiency |
%
|
88,2-89,8
|
88,2-89,8
|
88,2-89,8
|
88,2-89,8
|
| Max. work pressure allowed |
bar
|
1,5
|
1,5
|
1,5
|
1,5
|
| Required chimney flue |
Pa
|
25
|
29
|
32
|
34
|
| Water temp. on supply min/max |
°C
|
55/85
|
55/85
|
55/85
|
55/85
|
| Boiler weight |
kg
|
589
|
679
|
775
|
820
|
| Boiler water capacity |
l
|
77
|
99
|
116
|
142
|
| Chimney cross section |
cm x cm
ø mm |
14x14
160 |
16x16
180 |
18x18
200 |
19x19
210 |
| Minimum chimney height |
m
|
8
|
9
|
10
|
10
|
| Power supply |
V/Hz
|
230/50
|
230/50
|
230/50
|
230/50
|
| Power consumption |
W
|
158
|
158
|
264
|
264
|
| Width |
mm
|
1292
|
1322
|
1382
|
1382
|
| Depth |
mm
|
1034
|
1144
|
1244
|
1364
|
| Height* |
mm
|
1360
|
1360
|
1380
|
1480
|
| Supply and return diameter Dn |
mm
|
G 11/2"
|
G 11/2"
|
G 11/2"
|
G 11/2"
|
| Flue pipe dimension |
mm
|
ø178
|
ø178
|
ø194
|
ø194
|
| Height to the lower end of flue pipe* | mm | 919 | 919 | 931 | 931 |
| *Boiler’s height can be additionally regulated by the use of the feet attached to it. The feet can regulate height by 38-50mm. | |||||
![]() |
||||||||||||
| A* | B* | C | D* | E* | F | G | H | I | J | K | L | |
| 19 | 387 | 919 | Ø179 | 1360 | 1360 | 488 | 56 | 1325 | 747 | 110 | 178 | 1055 |
| 28 | 387 | 919 | Ø179 | 1360 | 1360 | 538 | 56 | 1375 | 857 | 110 | 198 | 1145 |
| 38 | 387 | 931 | Ø194 | 1380 | 1360 | 588 | 56 | 1421 | 957 | 110 | 198 | 1245 |
| 50 | 387 | 931 | Ø194 | 1480 | 1480 | 588 | 56 | 1421 | 1077 | 110 | 198 | 1365 |
| 75 | 393 | 1080 | Ø245 | 1580 | 1580 | 688 | 56 | - | 1227 | 110 | 198 | 1535 |
| * In case of disclaimers of regulatory dimension increases from min. 38 to max. 50 mm. | |||||
| The table below shows the dimensions of the opening for filling and combustion chamber. | |||||
| A (Width) |
B (Depth) |
C (Height) |
D (Width x Height) |
![]() |
|
| 19 | 304 | 355 | 245 | 304x164 | |
| 28 | 354 | 355 | 245 | 354x164 | |
| 38 | 404 | 455 | 245 | 404x184 | |
| 50 | 404 | 455 | 305 | 404x234 | |
| 75 | 504 | 605 | 395 | 504x234 | |
|
DEFRO Company reserves the right to change without notice the technical parameters, equipment and specifications of our products. Contained on this page to ensure the information is not in the meaning. 4. 3 and 4 of the Act of 27 July 2002 on the specific terms of consumer sales and amending the Civil Code (the "Act") and do not describe the purpose of a product. 4. 2 of the Act. This site does not constitute an offer within the meaning of. 1966 Civil Code.
|