Optima

New design and technically improved OPTIMA boilers refer back to the previous generation of OPTIMA boilers in terms of their construction. Vertical combustion channels increase flue gas circulation allowing for maximum usage of thermal energy and improving efficiency of the device. The boilers are adjusted for combustion of solid fuels such as coal, coal and fines mixture, wood, wood chips and sawdust. A big chamber allows for charging fuel enough for many hours of operation. The combustion process does not require electrical power supply - the boilers use natural air draught. The device has been adjusted for installation of the DEFRO blow-in set, which controls the combustion process electronically. All the technical solutions ensure high comfort of usage, long-term and failure-free operation and cost efficiency. Reduced number of welded joints decrease the risk of leakage. In order to facilitate boiler installation in the boiler room, the devices have been equipped with attachable and adjustable legs.

 

optima-przekroj
Fuel type
primary substitute

wegiel-orzech

wegiel-mial drewno_kawalki zrzynki-wiory
coal (nut type) coal / fine coal
wood
edgings, shavings

Boiler’s advantages:
gwarancja-3
3-year warranty for heat exchanger tightness, 2-year warranty for other elements and efficient operation of the boiler;
stal-6 the exchanger has been made from certified boiler steel ( P256GH type) of thickness of 6 mm, delivered by the following steel plants: Arcelor Mittal Poland S.A, Kraków branch and U. S. Steel Košice s.r.o.;
sprawnosc-80
high thermal efficiency, up to 80%, thanks to increased heat recovery from flue gas - multi-draught system of vertical combustion channels;
nadmuch adjusted for installation of a blow-in set;
ruszt-ruchomy
mechanical movable grate for removing ash from water grate bars (not applicable for 10 and 13 types);
miarkownik-ciagu
regulation of the combustion process by means of the draught regulator* or a handwheel located in the ash pan door;
czopuch-regulacja
flue extension with flue gas draught regulation;
regulowane-stopki adjustable legs facilitating levelling of the boiler;
Technical data
Unit 10 13 15 18 20 24 30 40
Nominal output kW 5-16 6-18 6-20 7-22 8-25 9-28 11-36 15-48
Heating surface m2 1,4 1,6 1,8 2,0 2,2 2,5 3,2 4,3
Heated room surface m2 up to 100 up to 130 up to 150 up to 180 up to 200 up to 240 up to 280 up to 360
Single fuel load kg ~18 ~21 ~23 ~26 ~32 ~43 ~62 ~68
Optimum heating efficiency % 80,1-80,4 80,1-80,4 80,1-80,4 80,1-80,4 80,1-80,4 80,1-80,4 80,1-80,4 80,1-80,4
Max. work pressure allowed bar 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5
Required chimney flue Pa 21 22 24 25 26 28 30 32
Water temp. on supply max °C 90 90 90 90 90 90 90 90
Boiler weight kg 241 254 276 301 326 360 439 519
Boiler water capacity l 43 47 55 60 65 78 94 121
Chimney cross section cm x cm
ø mm
14x14
160
14x14
160
14x14
160
14x14
160
14x14
160
15x15
170
17x17
190
19x19
210
Minimum chimney height m 6 6 6 7 7 7 8 8
Power supply
V/Hz - - - - - - - -
Power consumption
W - - - - - - - -
Width mm 650 650 675 675 725 725 775 825
Depth mm 976 976 1076 1076 1076 1116 1176 1266
Height* mm 921 971 991 1051 1051 1121 1171 1231
Supply and return diameter Dn mm G 11/2" G 11/2" G 11/2" G 11/2" G 11/2" G 11/2" G 11/2" G 11/2"
Flue pipe dimension mm ø178 ø178 ø178 ø178 ø178 ø178 ø178 ø178
Height to the lower end of flue pipe* mm 503 550 570 633 633 701 751 811
*Boiler’s height can be additionally regulated by the use of the feet attached to it. The feet can regulate height by 28-40mm.

optima-wymiary

  A* B C D* E F G H I J
10 233 503 Ø179 921 650** 448 225 640 111 976
13 233 550 Ø179 971 650** 448 225 640 111 976
15 233 570 Ø179 991 675 448 225 740 111 1086
18 233 633 Ø179 1051 675 448 225 740 111 1086
20 233 633 Ø179 1051 725 538 225 740 111 1086
24 233 701 Ø179 1121 725 538 225 780 111 1126
30 233 751 Ø179 1171 725 588 225 840 111 1176
40 233 811 Ø179 1231 825 638 225 930 111 1266
* In case of disclaimers of regulatory dimension increases from min. 28 to max. 40 mm.
** Boilers OPTIMA 10 and OPTIMA 13 do not have a movable grate.

The table below shows the dimensions of the opening for filling and combustion chamber. Due to the changing depth of the combustion chamber are the smallest dimension of / at the top of the chamber and / greatest / just above grille /.

  A
(Width)
B
(Depth)
C
(Height)
D
(Width x Height)
optima-wymiary-przekroj
10 308 150-330 260 308x188
13 308 160-330 260 308x188
15 308 225-410 280 308x188
18 308 225-410 340 308x188
20 358 225-410 340 358x188
24 358 255-450 410 358x188
30 408 310-510 460 408x188
40 458 310-510 520 458x188





 
DEFRO Company reserves the right to change without notice the technical parameters, equipment and specifications of our products. Contained on this page to ensure the information is not in the meaning. 4. 3 and 4 of the Act of 27 July 2002 on the specific terms of consumer sales and amending the Civil Code (the "Act") and do not describe the purpose of a product. 4. 2 of the Act. This site does not constitute an offer within the meaning of. 1966 Civil Code.


heat exchanger made of 6mm thick certified boiler steel (P265GH) brought from T. Sendzimir Steel Mill - ArcelorMittal Group;