Optima Plus
|
The new OPTIMA PLUS series means state-of-the-art technical solutions and modern design. In terms of construction solutions, the boilers are based on the OPTIMA series with all advantages including the reduced number of welded joints decreasing the risk of leakage. A big combustion chamber, location of cleaning holes, adjustable legs facilitating levelling of the boiler as well as the flue extension possibility allowing for easier connection to the chimney are only some of solutions ensuring high comfort of usage. User-friendly regulation of the combustion process with the possibility of upgrading the automatics, based on the PID algorithm, allows for reduction of fuel consumption by over 10%. The new series of boilers has retained the feature of multiple-point air blow-in into the area of charged fuel and the solution for comfortable cleaning of air nozzles. Pumping the air directly to the area of fuel combustion increases the efficiency of operation and guarantees uniform and long-lasting combustion process ensuring its stability. |
|
|||||||||||||||||||||
| Fuel type |
||||||||||||||||||||||
| primary | substitute | |||||||||||||||||||||
![]() |
![]() |
![]() |
![]() |
|||||||||||||||||||
| coal (nut-type) | coal/fine coal |
wood | edgings, shavings | |||||||||||||||||||
|
||||||||||||||||||||||
| Technical data | |||||||||
| Specification/boiler type | Unit | 10 | 13 | 15 | 18 | 20 | 24 | 30 | 40 |
| Nominal output | kW | 5-16 | 6-18 | 6-20 | 7-22 | 8-25 | 9-28 | 11-36 | 15-48 |
| Heating surface | m2 | 1,4 | 1,6 | 1,8 | 2,0 | 2,2 | 2,5 | 3,2 | 4,3 |
| Heated room surface | m2 | do 100 | do 130 | do 150 | do 180 | do 200 | do 240 | do 280 | do 360 |
| Single fuel load | kg | ~18 | ~20 | ~23 | ~26 | ~32 | ~43 | ~62 | ~68 |
| Optimum heating efficiency | % | ~80,2-80,9 | ~80,2-80,9 | ~80,2-80,9 | ~80,2-80,9 | ~80,2-80,9 | ~80,2-80,9 | ~80,2-80,9 | ~80,2-80,9 |
| Max. work pressure allowed | bar | 1,5 | 1,5 | 1,5 | 1,5 | 1,5 | 1,5 | 1,5 | 1,5 |
| Required chimney flue | Pa | 21 | 22 | 24 | 25 | 26 | 28 | 30 | 32 |
| Water temp. on supply max | °C | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 |
| Boiler weight | kg | 241 | 264 | 276 | 311 | 331 | 368 | 445 | 525 |
| Boiler water capacity | l | 43 | 47 | 55 | 60 | 65 | 78 | 94 | 121 |
| Chimney cross section | cm x cm ø mm |
14x14 160 |
14x14 160 |
14x14 160 |
14x14 160 |
14x14 160 |
16x16 170 |
17x17 190 |
19x19 210 |
| Minimum chimney height | m | 6 | 6 | 7 | 7 | 7 | 8 | 8 | 9 |
| Power supply |
V/Hz | 230/50 | 230/50 | 230/50 | 230/50 | 230/50 | 230/50 | 230/50 | 230/50 |
| Power consumption |
W | 39 | 39 | 39 | 39 | 39 | 39 | 39 | 39 |
| Width | mm | 719 | 719 | 719 | 719 | 769 | 769 | 819 | 869 |
| Depth | mm | 976 | 976 | 1086 | 1086 | 1086 | 1126 | 1176 | 1266 |
| Height* | mm | 921 | 971 | 991 | 1051 | 1051 | 1121 | 1171 | 1231 |
| Supply and return diameter Dn | mm | G 11/2" | G 11/2" | G 11/2" | G 11/2" | G 11/2" | G 11/2" | G 11/2" | G 11/2" |
| Flue pipe dimension | mm | ø178 | ø178 | ø178 | ø178 | ø178 | ø178 | ø178 | ø178 |
| *Boiler’s height can be additionally regulated by the use of the feet attached to it. The feet can regulate height by 28-40mm. | |||||||||
![]() |
||||||||||
| A* | B* | C | D* | E | F | G | H | I | J | |
| 10 | 233 | 503 | Ø179 | 921 | 719 | 448 | 225 | 640 | 111 | 976 |
| 13 | 233 | 550 | Ø179 | 971 | 719 | 448 | 225 | 640 | 111 | 976 |
| 15 | 233 | 570 | Ø179 | 991 | 719 | 448 | 225 | 740 | 111 | 1086 |
| 18 | 233 | 633 | Ø179 | 1051 | 719 | 448 | 225 | 740 | 111 | 1086 |
| 20 | 233 | 633 | Ø179 | 1051 | 769 | 538 | 225 | 740 | 111 | 1086 |
| 24 | 233 | 701 | Ø179 | 1121 | 769 | 538 | 225 | 780 | 111 | 1126 |
| 30 | 233 | 751 | Ø179 | 1171 | 819 | 588 | 225 | 840 | 111 | 1176 |
| 40 | 233 | 811 | Ø179 | 1231 | 869 | 638 | 225 | 930 | 111 | 1266 |
| * In case of disclaimers of regulatory dimension increases from min. 28 to max. 40 mm. ** Boilers OPTIMA 10 and OPTIMA 13 do not have a movable grate. |
|||||
| The table below shows the dimensions of the opening for filling and combustion chamber. Due to the changing depth of the combustion chamber are the smallest dimension of / at the top of the chamber and / greatest / just above grille /. | |||||
| A (Width) |
B (Depth) |
C (Height) |
D (Width x Height) |
![]() |
|
| 10 | 308 | 150-330 | 260 | 308x188 | |
| 13 | 308 | 160-330 | 260 | 308x188 | |
| 15 | 308 | 225-410 | 280 | 308x188 | |
| 18 | 308 | 225-410 | 340 | 308x188 | |
| 20 | 358 | 225-410 | 340 | 358x188 | |
| 24 | 358 | 255-450 | 410 | 358x188 | |
| 30 | 408 | 310-510 | 460 | 408x188 | |
| 40 | 458 | 310-510 | 520 | 458x188 | |
|
DEFRO Company reserves the right to change without notice the technical parameters, equipment and specifications of our products. Contained on this page to ensure the information is not in the meaning. 4. 3 and 4 of the Act of 27 July 2002 on the specific terms of consumer sales and amending the Civil Code (the "Act") and do not describe the purpose of a product. 4. 2 of the Act. This site does not constitute an offer within the meaning of. 1966 Civil Code.
|