Defro Kompakt Max
|
DEFRO KOMPAKT MAX automatic boilers can be distinguished by their high usage safety and high durability. It is guaranteed by such structural characteristics as: broad water jacket with good internal circulation and sound heat transfer, large spaces between tubes, and the heat exchanger made of 8-10 mm boiler steel. Control and safety equipment adjusted for the user's needs are at standard delivery range. Large cleanout availability and sufficient number of inspection holes on both sides of the boiler assure optimum service comfort, thus reducing maintenance costs. |
|
||||||||||||||||||||
| Fuel | |||||||||||||||||||||
| primary | |||||||||||||||||||||
![]() |
|||||||||||||||||||||
| pea-coal | |||||||||||||||||||||
|
|||||||||||||||||||||
| Technical data | ||||||
| Specification/boiler type | Unit | 75 | 100 | 150 | 200 | 250 |
| Nominal output | kW | 22,5-75 | 30-100 | 45-150 | 60-200 | 75-250 |
| Heating surface | m2 | 7,7 | 10 | 14 | 17 | 26 |
| Heated room surface | m2 | 450-700 | 700-1000 | 1000-1300 | 1300-1500 | 1500-2000 |
| Single fuel load | kg | ~570 | ~570 | ~570 | ~570 | ~570 |
| Optimum heating efficiency | % | ~91 | ~91 | ~91 | ~91 | ~91 |
| Max. work pressure allowed | MPa | 1,5 | 1,5 | 1,5 | 1,5 | 2,0 |
| Required chimney flue | Pa | 38 | 40 | 44 | 46 | 48 |
| Water temp. on supply max | °C | 80 | 80 | 80 | 80 | 80 |
| Boiler weight | kg | 1150 | 1750 | 1950 | 2500 | 2550 |
| Boiler water capacity | l | 380 | 650 | 800 | 1050 | 2150 |
| Chimney cross section | cm x cm ø mm |
24x24 270 |
27x27 300 |
32x32 360 |
37x37 410 |
40x40 450 |
| Minimum chimney height | m | 12 | 13 | 14 | 15 | 16 |
| Power supply |
V/Hz | 400/50 | 400/50 | 400/50 | 400/50 | 400/50 |
| Power consumption |
W | 289 | 659 | 659 | 809 | 809 |
| Width | mm | 1280 | 2422 | 2422 | 2680 | 2817 |
| Depth | mm | 1426 | 2132 | 2132 | 2332 | 2512 |
| Height | mm | 1706 | 1744 | 1944 | 2094 | 2343 |
| Supply and return diameter Dn | mm | G 2½" | G 2½" | G 2½" | G 2½" | G 2½" |
| Flue pipe dimension |
mm
|
230x205
|
250x310
|
300x310
|
350x310
|
350x310 |
| Height to the lower end of flue pipe | mm | 1279 | 1386 | 1389 | 1536 | 1786 |
| |
|
DEFRO Company reserves the right to change without notice the technical parameters, equipment and specifications of our products. Contained on this page to ensure the information is not in the meaning. 4. 3 and 4 of the Act of 27 July 2002 on the specific terms of consumer sales and amending the Civil Code (the "Act") and do not describe the purpose of a product. 4. 2 of the Act. This site does not constitute an offer within the meaning of. 1966 Civil Code.
|