homepage contact

Optima Komfort Plus

The construction of the OPTIMA KOMFORT PLUS BOILERS allows for dual system work and burning any type of fuels - fines when firing up from the top (with combustion support of up to 20 hours) and other solid fuels (coal, wood, fines and coal mixture) when firing up from the bottom.
The boilers feature electronic control of air blow-in into the combustion chamber allowing for more precise temperature regulation increasing operation comfort. The system of multiple-point air blow-in into the area of charged fuel increases stability and efficiency of boiler operation.

 

optima-komfort-plus
Fuel type
primary substitute
mial_weglowy wegiel-orzech wegiel-mial zrzynki-wiory
fine coal nut coal coal/fine coal edgings, shavings
Boiler’s advantages:
gwarancja-4
4-year warranty for heat exchanger tightness, 2-year warranty for other elements and eficient operation of the boiler;
stal-6 the exchanger has been made from certified boiler steel ( P256GH type) of thickness of 6 mm, delivered by the following steel plants: Arcelor Mittal Poland S.A, Kraków branch and U. S. Steel Košice s.r.o.;
sprawnosc-80
high thermal efficiency, up to 80%, thanks to increased heat recovery from flue gas - multi-draught system of vertical combustion channels;
sterownik-2 electronic control of the boiler;
programmer cooperating with 2 pumps (central heating and hot utility water) and with output for a room controller;
ruszt-ruchomy mechanical movable grate for removing ash from water grate bars;
powietrze-wielopunkt multiple-point air blow-in into the area of charged fuel;
duza-komora
big combustion chamber;
dwa-tryby
two modes of operation - fired up from the top as a fines boiler (combustion support up to 20h) or
as a universal boiler fired up from the bottom (for hard coal of other assortments and wood);
Technical data
Unit 12 15 20 25 30 35
Nominal output kW 6-12 6-19 8-24 9-28 11-35 12-40
Heating surface m2 1,5 1,7 2,1 2,5 3,1 3,6
Heated room surface m2 do 120 do 150 do 200 do 260 do 300 do 350
Single fuel load kg ~21 ~30 ~40 ~50 ~60 ~70
Optimum heating efficiency % ~80 ~80 ~80 ~80 ~80 ~80
Max. work pressure allowed bar 1,5 1,5 1,5 1,5 1,5 1,5
Required chimney flue Pa 22 23 26 28 30 31
Water temp. on supply max °C 85 85 85 85 85 85
Boiler weight kg 235 260 305 350 380 415
Boiler water capacity l 59 58 68 76 105 112
Chimney cross section cm x cm
ø mm
14x14
160
14x14
160
14x14
160
16x16
160
17x17
190
18x18
200
Minimum chimney height m 6 6 7 7 8 8
Power supply V/Hz 230/50 230/50 230/50 230/50 230/50 230/50
Power consumption W 82 82 82 82 82 82
Width mm 565 615 615 665 765 765
Depth mm 1010 1010 1080 1110 1110 1180
Height mm 1460 1510 1570 1570 1570 1570
Supply and return diameter Dn mm G 11/2" G 11/2" G 11/2" G 11/2" G 2" G 2"
Flue pipe dimension mm 150x185 150x185 150x185 180x185 200x185 200x185
s-okp
  A B C D E F G H I J K
12 265 940 1205 1460 430 565 540 260 1010 185 150
15 265 990 1255 1510 480 615 540 260 1010 185 150
20 265 1050 1315 1570 480 615 610 260 1080 185 150
25 265 1050 1315 1570 530 665 640 260 1110 185 180
30 265 1050 1315 1570 630 765 640 260 1110 185 200
35 265 1050 1315 1570 630 765 710 260 1180 185 200
W tabeli poniżej podano wymiary otworu zasypowego oraz komory paleniskowej.
  A
(Width)
B
(Depth)
C
(Height)
D
(Width x Height)
s-okp-x
12 258 375 290 258x188
15 308 375 345 308x188
20 308 445 405 308x188
25 358 470 405 358x188
30 458 470 405 458x188
35 458 530 405 458x188
 
DEFRO company reserves the right to make equipment, technological or specification changes without notice due to continuing engineering and technological advances. The content of this website does not constitute an assurance within the meaning of Article 4.3-4 of the Act of 27 August 2002 on specific terms and conditions of consumer sale and amendments to the Civil Code (“the Act”) neither is a product description within the meaning of Article 4.2 of the Act. This website and all the information it contains are issued for information purposes only and they do not constitute an offer within the meaning of article 66 of the Civil Code.


stal-6