Optima Plus

The OPTIMA PLUS boiler series is an upgraded version of OPTIMA boilers. State-of-the-art, electronic control of air blow-in into the combustion chamber significantly increases the comfort of operation, increases combustion time and allows for even more precise temperature control. The system of multiple-point air blow-in into the area of charged fuel increases stability and efficiency of boiler operation.
The heat exchanger, made from P265GH boilerplate, has a significant impact on durability of the boiler and is insulated with mineral wool and covered by steel sheets.

 

optima-plus
Fuel type
primary substitute
wegiel-orzech wegiel-mial drewno_kawalki zrzynki-wiory
nut coal coal/fine coal wood edgings, shavings

Boiler’s advantages:
gwarancja-3
3-year warranty for heat exchanger tightness, 2-year warranty for other elements and efficient operation of the boiler;
stal-6 the exchanger has been made from certified boiler steel ( P256GH type) of thickness of 6 mm, delivered by the following steel plants: Arcelor Mittal Poland S.A, Kraków branch and U. S. Steel Košice s.r.o.;
sprawnosc-80
high thermal efficiency, up to 80%, thanks to increased heat recovery from flue gas - multi-draught system of vertical combustion channels;
sterownik-2 electronic control of the boiler;
programmer cooperating with 2 pumps (central heating and hot utility water) and with output for a room controller;
ruszt-ruchomy
mechanical movable grate for removing ash from water grate bars (not applicable for 10 and 13 types);
zakres-mocy
wide range of power;
duza-komora
big combustion chamber;
powietrze-wielopunkt multiple-point air blow-in into the area of charged fuel; 
Technical data
Unit 10 13 15 18 20 24 30 40
Nominal output kW 5-14 5-16 6-19 7-21 8-24 9-27 10-33 14-46
Heating surface m2 1,2 1,4 1,7 1,9 2,1 2,4 3,0 4,1
Heated room surface m2 up to 80 up to 100 up to 120 up to 150 up to 180 up to 220 up to 260 up to 360
Single fuel load kg ~16 ~20 ~22 ~25 ~30 ~40 ~60 ~65
Optimum heating efficiency % ~80 ~80 ~80 ~80 ~80 ~80 ~80 ~80
Max. work pressure allowed bar 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5
Required chimney flue Pa 21 22 24 25 26 28 30 32
Water temp. on supply max °C 85 85 85 85 85 85 85 85
Boiler weight kg 205 215 240 270 290 320 375 455
Boiler water capacity l 42 47 51 58 62 73 98 109
Chimney cross section cm x cm
ø mm
14x14
160
14x14
160
14x14
160
14x14
160
14x14
160
16x16
180
17x17
190
19x19
210
Minimum chimney height m 6 6 7 7 7 8 8 9
Power supply V/Hz 230/50 230/50 230/50 230/50 230/50 230/50 230/50 230/50
Power consumption W 82 82 82 82 82 82 82 82
Width mm 540 540 645 645 695 695 755 795
Depth mm 1120 1120 1220 1220 1220 1260 1320 1410
Height mm 1050 1100 1120 1175 1175 1245 1295 1355
Supply and return diameter Dn mm G 11/2" G 11/2" G 11/2" G 11/2" G 11/2" G 2" G 2" G 2"
Flue pipe dimension mm 170x160 170x160 180x180 180x180 180x180 200x180 200x180 200x200

s-op

  A B C D E F G H I J K L
10 265 540 790 1050 480 - 650 261 1120 170 160 30
13 265 590 840 1100 480 - 650 261 1120 170 160 30
15 265 600 860 1120 480 645 750 261 1220 180 180 30
18 265 660 920 1175 480 645 750 261 1220 180 180 30
20 265 660 920 1175 530 695 750 261 1220 180 180 30
24 265 710 990 1245 530 695 790 261 1260 200 180 30
30 270 760 1040 1295 590 755 850 261 1320 200 180 30
40 270 820 1100 1355 630 795 940 261 1410 200 200 30

W tabeli poniżej podano wymiary otworu zasypowego oraz komory paleniskowej. Ze względu na zmieniającą się głębokość komory paleniskowej podano wymiar najmniejszy /u góry komory/ oraz największy /tuż nad ruszetem/.

  A
(Width)
B
(Depth)
C
(Height)
D
(Width x Height)
s-op-x
10 308 165-325 255 308x188
13 308 165-325 280 308x188
15 308 225-400 250 308x188
18 308 225-400 310 308x188
20 358 225-400 310 358x188
24 358 260-440 380 358x188
30 418 320-505 430 358x188
40 458 310-510 490 358x188





 
DEFRO company reserves the right to make equipment, technological or specification changes without notice due to continuing engineering and technological advances. The content of this website does not constitute an assurance within the meaning of Article 4.3-4 of the Act of 27 August 2002 on specific terms and conditions of consumer sale and amendments to the Civil Code (“the Act”) neither is a product description within the meaning of Article 4.2 of the Act. This website and all the information it contains are issued for information purposes only and they do not constitute an offer within the meaning of article 66 of the Civil Code.