Optima
|
The OPTIMA series boilers are incredibly popular due to their versatility. The boilers are adjusted for both hard coal and firewood. The basic version features mechanical temperature regulation by means of a dumping door hand-wheel located in the ash pan door. The temperature can also be adjusted using a draught regulator (additional equipment). The boilers are adjusted for installation of an exhaust fan and electronic control panel, which significantly enhances the comfort of usage. |
![]() |
|||||||||||||||||||||
| Fuel type | ||||||||||||||||||||||
| primary | substitute | |||||||||||||||||||||
![]() |
![]() |
![]() |
![]() |
|||||||||||||||||||
| nut coal | coal/fine coal | wood | edgings, shavings | |||||||||||||||||||
|
||||||||||||||||||||||
| Technical data | |||||||||
| Specification/boiler type | Unit | 10 | 13 | 15 | 18 | 20 | 24 | 30 | 40 |
| Nominal output | kW | 5-14 | 5-16 | 6-19 | 7-21 | 8-24 | 9-27 | 10-33 | 14-46 |
| Heating surface | m2 | 1,2 | 1,4 | 1,7 | 1,9 | 2,1 | 2,4 | 3,0 | 4,1 |
| Heated room surface | m2 | up to 80 | up to 100 | up to 120 | up to 150 | up to 180 | up to 220 | up to 260 | up to 360 |
| Single fuel load | kg | ~16 | ~20 | ~22 | ~25 | ~30 | ~40 | ~60 | ~65 |
| Optimum heating efficiency | % | ~80 | ~80 | ~80 | ~80 | ~80 | ~80 | ~80 | ~80 |
| Max. work pressure allowed | bar | 1,5 | 1,5 | 1,5 | 1,5 | 1,5 | 1,5 | 1,5 | 1,5 |
| Required chimney flue | Pa | 21 | 22 | 24 | 25 | 26 | 28 | 30 | 32 |
| Water temp. on supply max | °C | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 |
| Boiler weight | kg | 190 | 205 | 235 | 260 | 285 | 310 | 365 | 420 |
| Boiler water capacity | l | 42 | 47 | 51 | 58 | 62 | 73 | 98 | 109 |
| Chimney cross section | cm x cm ø mm |
14x14 160 |
14x14 160 |
14x14 160 |
14x14 160 |
14x14 160 |
15x15 170 |
17x17 190 |
19x19 210 |
| Minimum chimney height | m | 6 | 6 | 6 | 7 | 7 | 7 | 8 | 8 |
| Power supply | V/Hz | - | - | - | - | - | - | - | - |
| Power consumption | W | - | - | - | - | - | - | - | - |
| Width | mm | 540 | 540 | 645 | 645 | 695 | 695 | 755 | 795 |
| Depth | mm | 1120 | 1120 | 1220 | 1220 | 1220 | 1260 | 1320 | 1410 |
| Height | mm | 790 | 840 | 860 | 920 | 920 | 990 | 1040 | 1100 |
| Supply and return diameter Dn | mm | G 11/2" | G 11/2" | G 11/2" | G 11/2" | G 11/2" | G 2" | G 2" | G 2" |
| Flue pipe dimension | mm | 170x160 | 170x160 | 180x180 | 180x180 | 180x180 | 180x180 | 180x180 | 180x180 |
![]() |
|||||||||||
| |
A | B | C | D | E | F | G | H | I | J | K |
| 10 | 265 | 540 | 790 | 480 | - | 650 | 261 | 1120 | 170 | 160 | 30 |
| 13 | 265 | 590 | 840 | 480 | - | 650 | 261 | 1120 | 170 | 160 | 30 |
| 15 | 265 | 600 | 860 | 480 | 645 | 750 | 261 | 1220 | 180 | 180 | 30 |
| 18 | 265 | 660 | 920 | 480 | 645 | 750 | 261 | 1220 | 180 | 180 | 30 |
| 20 | 265 | 660 | 920 | 530 | 695 | 750 | 261 | 1220 | 180 | 180 | 30 |
| 24 | 265 | 710 | 990 | 530 | 695 | 790 | 261 | 1260 | 200 | 180 | 30 |
| 30 | 270 | 760 | 1040 | 590 | 755 | 850 | 261 | 1320 | 200 | 180 | 30 |
| 40 | 270 | 820 | 1100 | 630 | 795 | 940 | 261 | 1410 | 200 | 200 | 30 |
| W tabeli poniżej podano wymiary otworu zasypowego oraz komory paleniskowej. Ze względu na zmieniającą się głębokość komory paleniskowej podano wymiar najmniejszy /u góry komory/ oraz największy /tuż nad ruszetem/. | |||||
| |
A (Width) |
B (Depth) |
C (Height) |
D (Width x Height) |
![]() |
| 10 | 308 | 165-325 | 255 | 308x188 | |
| 13 | 308 | 165-325 | 280 | 308x188 | |
| 15 | 308 | 225-400 | 250 | 308x188 | |
| 18 | 308 | 225-400 | 310 | 308x188 | |
| 20 | 358 | 225-400 | 310 | 358x188 | |
| 24 | 358 | 260-440 | 380 | 358x188 | |
| 30 | 418 | 320-505 | 430 | 358x188 | |
| 40 | 458 | 310-510 | 490 | 358x188 | |
| |
|
DEFRO company reserves the right to make equipment, technological or specification changes without notice due to continuing engineering and technological advances. The content of this website does not constitute an assurance within the meaning of Article 4.3-4 of the Act of 27 August 2002 on specific terms and conditions of consumer sale and amendments to the Civil Code (“the Act”) neither is a product description within the meaning of Article 4.2 of the Act. This website and all the information it contains are issued for information purposes only and they do not constitute an offer within the meaning of article 66 of the Civil Code.
|