Delta boilers are designed for burning both anthracite coal and firewood. The combustion process is mechanically controlled using a knob for the damper in the ashpan door. Additionally, there is an adjustable baffle in the loading door to regulate the secondary air intake. This solution significantly improves the combustion process and exhaust emission parameters. It is also possible to adjust the combustion process using a draft regulator. Furthermore, the boilers are factory-ready for the installation of a fan and electronic controller. The boilers have the advantage of a spacious combustion chamber that ensures extended operation of the device, as well as large loading doors that facilitate fuel loading.
3Optional, available at an additional cost, installed upon the customer’s request.
4The grate’s movable foot is not available in the 8 kW model.
5The draft regulator is not included as part of the boiler’s equipment.
Boiler name | Delta – Table No. 1 – power range 8 – 22 kW. | |||||
Boiler specification/type | IU | 8 | 12 | 16 | 19 | 22 |
Power range | kW | 2,4
-8 |
3,6
– 12 |
4,8
-16 |
5,7
-19 |
6,6
-22 |
Heating surface | m2 | 1,2 | 1,4 | 1,8 | 2,0 | 2,2 |
Area of heated rooms 1 | m2 | Up to 110 | Up to 140 | Up to 180 | Up to 200 | Up to 230 |
Single fuel load. | kg | ~13 | ~18 | ~23 | ~23 | ~28 |
Optimum thermal efficiency | % | 80,7-82 % | ||||
Energy efficiency class | – | D | D | C | C | D |
Max. permissible pressure
working |
bar | Open system 1.5 / Closed system 2.5. | ||||
Required exhaust gas draft | Pa | 18 | 21 | 24 | 26 | 27 |
Water temperature.
At supply max. |
°C | 65/90 | ||||
Boiler weight 2. | kg | 231 | 258 | 289 | 302 | 325 |
Boiler water capacity | l | 49 | 55 | 70 | 74 | 82 |
Cross-section of the chimney | cmxcm | 14×14 | 14×14 | 14×14 | 14×14 | 15×15 |
Cross-section of the chimney | O mm | 160 | 160 | 160 | 160 | 165 |
Minimum height.
Chimney |
m | 5 | 5 | 6 | 6,5 | 7 |
Width | mm | 646 | 646 | 646 | 646 | 696 |
Depth | mm | 990 | 1082 | 1094 | 1094 | 1094 |
Height | mm | 975 | 975 | 1075 | 1125 | 1125 |
Supply diameter.
and return Dn |
mm | G1 1” | ||||
Flue diameter | mm | 159 | 159 | 159 | 159 | 159 |
Height to the lower.
edge of the flue |
mm | 573 | 573 | 673 | 723 | 723 |
Hopper chamber dimensions.
as well as the loading opening dimensions. |
width
depth height width x height |
258
270 240 258×208 |
258
365 240 258×208 |
258
404 280 258×238 |
258
404 280 258×288 |
308
404 280 308×288 |
1Maximum heated area estimated for individual heat demand of q=95 W/m².
2The weight of the boiler depends on the equipment.
3Optional, available at an additional cost, installed upon the customer’s request.
4The grate’s movable foot is not available in the 8 kW model.
5The draft regulator is not included as part of the boiler’s equipment.
Boiler name | Delta – Table No. 2 – power range 25 – 49 kW. | |||||
Boiler specification/type | IU | 25 | 28 | 35 | 42 | 49 |
Power range | kW | 7,5
-25 |
8,4-
28 |
10,5
-35 |
12,6
-42 |
14,7
-49 |
Heating surface | m2 | 2,4 | 2,7 | 3,2 | 4,2 | 4,9 |
Area of heated rooms 1 | m2 | Up to 250 | Up to 280 | Up to 350 | Up to 440 | Up to 500 |
Single fuel load. | kg | ~32 | ~37 | ~51 | ~56 | ~61 |
Optimum thermal efficiency | % | 80,7-82 % | ||||
Energy efficiency class | – | D | D | D | D | D |
Max. permissible pressure
working |
bar | Open system 1.5 / Closed system 2.5. | ||||
Required exhaust gas draft | Pa | 28 | 29 | 31 | 32 | 34 |
Water temperature.
At supply max. |
°C | 65/90 | ||||
Boiler weight 2. | kg | 354 | 382 | 429 | 489 | 555 |
Boiler water capacity | l | 90 | 98 | 114 | 136 | 158 |
Cross-section of the chimney | cmxcm | 16×16 | 16×16 | 18×18 | 20×20 | 21×21 |
Cross-section of the chimney | O mm | 175 | 185 | 200 | 220 | 235 |
Minimum height.
Chimney |
m | 7 | 7,5 | 8 | 8 | 8,5 |
Width | mm | 746 | 796 | 846 | 846 | 846 |
Depth | mm | 1094 | 1094 | 1114 | 1262 | 1410 |
Height | mm | 1125 | 1125 | 1175 | 1178 | 1180 |
Supply diameter.
and return Dn |
mm | G1 1” | ||||
Flue diameter | mm | 159 | 178 | 178 | 178 | 178 |
Height to the lower.
edge of the flue |
mm | 723 | 714 | 765 | 768 | 768 |
Hopper chamber dimensions.
as well as the loading opening dimensions. |
width
depth height width x height |
358
404 280 358×288 |
408
404 280 408×288 |
458
424 330 458×288 |
458
464 330 458×288 |
458
504 330 458×288 |
1Maximum heated area estimated for individual heat demand of q=95 W/m².
2The weight of the boiler depends on the equipment.
3Optional, available at an additional cost, installed upon the customer’s request.
4The grate’s movable foot is not available in the 8 kW model.
5The draft regulator is not included as part of the boiler’s equipment.