MODEL | DRX OPTI 350 F | DRX OPTI 450 F | |
---|---|---|---|
Air flow (100 Pa) | [m3/h] | 350 | 450 |
Performance range | [m3/h] | ||
Compress | [Pa] | 200 | 200 |
Type of heat recovery system | – |
diaphragmatic
|
diaphragmatic
|
Heat recovery efficiency*
|
[%] | 85,5 | 84 |
Energy consumption
|
[W] | 16-270 | 18-338 |
Power of the pre-heater | [W] | 500 | 500 |
Power supply
|
[V] | 230 | 230 |
Fan power consumption
|
[W] | 270 | 338 |
Sound power level
|
[dB(A)] | 45 | 45 |
Connection diameter | mm | 200 | 200 |
Connection system | – | horizontal | horizontal |
Mass | kg | 57 | 57 |
Fuse type | |||
Rated supply voltage and frequency
|
V/Hz | ||
Type of exchanger
|
|||
Filter class
|
– | M-5/ePM10 | M-5/ePM10 |
Declared type | – | bi-directional | bi-directional |
Type of drive installed
|
– |
stepless regulation of fan speed
|
stepless regulation of fan speed
|
Declared maximum internal coefficients. and external air leaks |
[%] |
internal 1,34,
external 1,69
|
internal 1,04,
external 1,31
|
JZE class**
|
– | A | A |
* Test conditions according to PN-EN 13141-7
|
– | ||
** according to Regulation (EU) No. 1254/2014
|
– |
Controller: