MODEL | DRX 300 V | DRX 400 V | DRX 500 V | |
---|---|---|---|---|
Air flow (100 Pa) | m3/h | 350 | 450 | 550 |
Performance range | m3/h | |||
Compress
|
Pa | 200 | 200 | 200 |
Type of heat recovery system
|
diaphragmatic
|
diaphragmatic
|
diaphragmatic
|
|
Heat recovery efficiency*
|
% | 83,1 | 87 | 85,3 |
Energy consumption
|
W | 16-166 | 18-338 | 18-338 |
Heater power
|
W | 1500 | 1500 | 1500 |
Fan power consumption | W | 166 | 338 | 338 |
Sound power level
|
dB(A) | 41 | 45 | 47 |
Connection diameter
|
mm | 200 | 200 | 200 |
Connection system
|
vertical
|
vertical
|
vertical
|
|
Libra
|
kg | 69 | 69 | 69 |
Fuse type
|
WTA 5X20 250V F-10A | WTA 5X20 250V F-10A | WTA 5X20 250V F-10A | |
Rated supply voltage and frequency | V/Hz | 230/50 | 230/50 | 230/50 |
Type of exchanger |
countercurrent – DRX version, enthalpic – DRX E variant |
countercurrent – DRX version, enthalpic – DRX E variant |
countercurrent – DRX version, enthalpic – DRX E variant |
|
Filter class
|
M-5/ePM10 | M-5/ePM10 | M-5/ePM10 | |
Declared type
|
bi-directional | bi-directional | bi-directional | |
Type of drive installed |
stepless regulation of fan speed |
stepless regulation of fan speed |
stepless regulation of fan speed |
|
Declared maximum internal coefficients. and external air leaks |
% | internal 2.63 external 1.56
|
internal 0.7 external 1.18
|
internal 0.56 external 0.94 |
JZE class**
|
– | A | A | A |
* Test conditions according to PN-EN 13141-7
|
– | |||
** according to Regulation (EU) No. 1254/2014
|
– |