A manually loaded boiler in which the fuel combustion process is electronically controlled based on the exhaust gas temperature. The controller also regulates the operation of the central heating pump and the domestic hot water pump. Air for the fuel combustion process is forced by a blower fan using a multipoint direct feed system into the fuel combustion zone, significantly improving the process parameters. The high efficiency of the device is ensured by the proven heat exchanger design with horizontal flue gas passages, and a fixed water grate that accelerates the heat uptake from the combustion chamber.
Efficient fuel loading is facilitated by a large, slanted loading opening, and the device’s extended working hours are made possible by a capacious loading chamber. An additional advantage of the boiler is the placement of the flue outlet at a 45° angle, which, in combination with the angled extension of the firebox door, makes it easy to adapt the boiler to existing boiler rooms.
(*) – additional paid option, installed upon customer’s request.
Boiler name | Optima Komfort Plus | ||||||||
Boiler specification/type | IU | 8 | 10 | 12 | 15 | 20 | 25 | 30 | 35 |
Power range | kW | 2,4-8 | 3,0-10 | 3,6-12 | 4,5-15 | 6,0-20 | 7,5-25 | 9,0-30 | 10,5-35 |
Heating surface | m2 | 1,2 | 1,5 | 1,6 | 2,0 | 2,6 | 2,9 | 3,6 | 3,9 |
Area of heated rooms 1 | m2 | Up to 110 | Up to 140 | Up to 150 | Up to 200 | to 260 | Up to 290 | Up to 350 | Up to 390 |
Single fuel load. | kg | ~12 | ~19 | ~19 | ~23 | ~31 | ~39 | ~49 | ~57 |
Optimum thermal efficiency | % | ~85,0 – 85,8 | |||||||
Energy efficiency class | – | D | D | D | D | D | D | D | D |
Max. permissible pressure
working |
bar | 1,5 | |||||||
Required exhaust gas draft | Pa | 18 | 20 | 22 | 23 | 26 | 28 | 30 | 31 |
Supply water temperature max. | °C | 65/85 | |||||||
Boiler weight 2 | kg | 200 | 253 | 258 | 289 | 319 | 372 | 434 | 480 |
Boiler water capacity | l | 36 | 50 | 53 | 60 | 72 | 82 | 87 | 111 |
Cross-section of the chimney | cmxcm | 14×14 | 14×14 | 14×14 | 14×14 | 14×14 | 16×16 | 17×17 | 18×18 |
Cross-section of the chimney | Ø mm | 160 | 160 | 160 | 160 | 160 | 180 | 190 | 200 |
Minimum height of the chimney | m | 5,5 | 5,5 | 6 | 6 | 7 | 7 | 8 | 8 |
Width | mm | 550 | 550 | 550 | 600 | 600 | 650 | 750 | 750 |
Depth / horizontal extension / | mm | 890 | 1045 | 1045 | 1045 | 1115 | 1145 | 1145 | 1215 |
Height / vertical extension / | mm | 1407 | 1530 | 1530 | 1570 | 1620 | 1625 | 1625 | 1640 |
Supply and return diameter Dn | mm | G1 ½” | |||||||
Flue diameter | mm | 127 | 178 | 178 | 178 | 178 | 178 | 178 | 178 |
Power supply | V/Hz | ~230/50 | |||||||
Maximum power consumption. | W | 39 | 45 | 45 | 45 | 45 | 45 | 45 | 45 |
Height to the lower edge of the firebox door / horizontal extension / | mm | 1080 | 1165 | 1165 | 1210 | 1260 | 1265 | 1265 | 1275 |
Hopper chamber dimensions.
as well as the loading opening dimensions. |
width
depth height width x height |
258
253 236 258 x 188 |
258
268 251 258 x 188 |
258
368 251 258 x 188 |
308
368 251 308 x 238 |
308
438 288 308 x 238 |
358
468 288 358 x 238 |
458
468 288 358 x 238 |
458
537 288 358 x 238 |
1 The maximum heated area estimated for individual heat demand of q=80 W/m².
2 The weight of the boiler depends on the equipment
Have more questions?
Would you like to ask about a discount?
Do you need device selection?
If you want to install a new heat source, it is worth paying attention to DEFRO devices, a Polish manufacturer with many years of experience in the heating industry. Our specialists will help you choose the right boiler and its power, and distributors and installers will take care of the assembly and commissioning, and all you need to do is enjoy the warmth and comfort. The distribution network of our products is divided into regions for which managers and salespeople are responsible.