The electrical connection is extremely simple and quick. It comes down to connecting the external unit with the hydromodule using a dedicated cable supplied with the heat pump, and then plugging the hydromodule into the plug socket using a cable with a plug, also included in the set. This minimizes the risk of making errors when connecting and significantly shortens the assembly time.
DEFRO DHP PREMIUM is a monoblock air-water heat pump of the latest generation, created especially for Polish climatic conditions. Designed and manufactured in Poland by the largest manufacturer of heating devices with 100% domestic capital. The device was tested by scientists from AGH.
Technical data | DHP PREMIUM 8 | DHP PREMIUM 12 | DHP PREMIUM 16 |
---|---|---|---|
Heating power / COP at A7 / W35* | 7,9 kW / 4,8 | 12,0 kW / 4,8 | 16,3 kW / 4,8 |
Heating power / COP at A2 / W35* | 6,1 kW / 3,8 | 9,0 kW / 3,8 | 13,0 kW / 4,0 |
Heating power / COP at A-7 / W35* | 5,4 kW / 3,5 | 7,6 kW / 3,2 | 10,7 kW / 3,3 |
Heating power / COP at A-15 / W35* | 4,5 kW / 2,9 | 7,0kW / 3,0 | 9,2 kW / 2,9 |
Energy efficiency class (supply temperature 35oC) | A++ | A++ | A++ |
Energy efficiency class (supply temperature 55oC) | A++ | A++ | A++ |
Minimum / maximum temperature of the central heating circuit. and C.W.U. | 10oC / 65oC | 10oC / 65oC | 10oC / 65oC |
Refrigerant / refrigerant mass | R290 / 1,2 kg | R290 / 1,4 kg | R290 / 3,5 kg |
Compressor type | Copeland Scroll | Copeland Scroll | Copeland Scroll |
Lower / upper air temperature limit for pump operation | -25oC / + 35oC | -25oC / + 35oC | -25oC / + 35oC |
Sound power level outdoor / outdoor night mode / indoor | 59 / 43 dB (A) | 60 / 36 dB (A) | 64 / 43 dB (A) |
Supply voltage of the heat pump | 3×400 V, 50 Hz | 3×400 V, 50 Hz | 3×400 V, 50 Hz |
Safeguard | C 20A | C 20A | C 20A |
Ground – outdoor unit | 209 kg | 215 kg | 228 kg |
DHP PREMIUM HB (BASIC) indoor unit – a set for cooperation with pellet or gas boilers.
1. Electrical connections and sensors,
2. Power supply from the outdoor unit,
3. Central heating supply connector and C.W.U.,
4. Colorful display ensuring
intuitive and easy access to the desired settings,
5. Metal housing of the hydromodule,
6. Circulation pump,
7. Flow meter,
8. Hydromodule controller